  1. What: /sys/bus/w1/devices/.../w1_master_timeout_us
  2. Date: April 2015
  3. Contact: Dmitry Khromov <dk@icelogic.net>
  4. Description: Bus scanning interval, microseconds component.
  5. Some of 1-Wire devices commonly associated with physical access
  6. control systems are attached/generate presence for as short as
  7. 100 ms - hence the tens-to-hundreds milliseconds scan intervals
  8. are required.
  9. see Documentation/w1/w1-generic.rst for detailed information.