IScsiConfigStrings.uni 6.9 KB

123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596
  1. // *++
  2. //
  3. // Copyright (c) 2004 - 2018, Intel Corporation. All rights reserved.<BR>
  4. // SPDX-License-Identifier: BSD-2-Clause-Patent
  5. //
  6. // Module Name:
  7. //
  8. // IScsiConfigStrings.uni
  9. //
  10. // Abstract:
  11. //
  12. // String definitions for iSCSI configuration.
  13. //
  14. // Revision History:
  15. //
  16. // --*/
  17. /=#
  18. #langdef en-US "English"
  19. #langdef x-UEFI-ns "UefiNameSpace"
  20. #string STR_ISCSI_CONFIG_FORM_TITLE #language en-US "iSCSI Configuration"
  21. #string STR_ISCSI_CONFIG_FORM_HELP #language en-US "Configure the iSCSI parameters."
  22. #string STR_ISCSI_MAIN_FORM_TITLE #language en-US "iSCSI Configuration"
  23. #string STR_ISCSI_MAC_FORM_TITLE #language en-US "MAC Selection"
  24. #string STR_ISCSI_CONFIG_INIT_NAME #language en-US "iSCSI Initiator Name"
  25. #language x-UEFI-ns "iSCSIInitiatorName"
  26. #string STR_ISCSI_CONFIG_INIT_NAME_HELP #language en-US "The worldwide unique name of iSCSI Initiator. Only IQN format is accepted."
  27. #string STR_ISCSI_ATTEMPT_NAME #language en-US "iSCSI Attempt Name"
  28. #string STR_ISCSI_ATTEMPT_NAME_HELP #language en-US "The human name defined for this attempt."
  29. #string STR_ISCSI_CONFIG_RETRY #language en-US "Connection Retry Count"
  30. #string STR_ISCSI_CONFIG_RETRY_HELP #language en-US "The minimum value is 0 and the maximum is 16. 0 means no retry."
  31. #string STR_ISCSI_CONFIG_TIMEOUT #language en-US "Connection Establishing Timeout"
  32. #string STR_ISCSI_CONFIG_TIMEOUT_HELP #language en-US "The timeout value in milliseconds. The minimum value is 100 milliseconds and the maximum is 20 seconds."
  33. #string STR_ADD_ATTEMPT_ENTRY #language en-US "Add an Attempt"
  34. #string STR_ISCSI_ATTEMPT_FORM_TITLE #language en-US "Attempt Configuration"
  35. #string STR_DEL_ATTEMPT_ENTRY #language en-US "Delete Attempts"
  36. #string STR_DEL_ATTEMPT_ENTRY_HELP #language en-US "Delete one or more attempts"
  37. #string STR_ORDER_ATTEMPT_ENTRY #language en-US "Change Attempt Order"
  38. #string STR_ISCSI_MODE_PROMPT #language en-US "iSCSI Mode"
  39. #string STR_ISCSI_MODE_HELP #language en-US "Disabled, Enabled, Enabled for MPIO"
  40. #string STR_ISCSI_MODE_DISABLED #language en-US "Disabled"
  41. #string STR_ISCSI_MODE_ENABLED #language en-US "Enabled"
  42. #string STR_ISCSI_MODE_ENABLED_FOR_MPIO #language en-US "Enabled for MPIO"
  43. #string STR_IP_MODE_PROMPT #language en-US "Internet Protocol"
  44. #string STR_IP_MODE_HELP #language en-US "Initiator IP address is system assigned in IP6 mode. In Autoconfigure mode, iSCSI driver will attempt to connect iSCSI target via IPv4 stack, if failed then attempt IPv6 stack."
  45. #string STR_IP_MODE_IP4 #language en-US "IP4"
  46. #string STR_IP_MODE_IP6 #language en-US "IP6"
  47. #string STR_IP_MODE_AUTOCONFIG #language en-US "Autoconfigure"
  48. #string STR_AUTHEN_TYPE_PROMPT #language en-US "Authentication Type"
  49. #string STR_AUTHEN_TYPE_HELP #language en-US "Authentication method: CHAP, Kerberos, or None"
  50. #string STR_AUTHEN_TYPE_CHAP #language en-US "CHAP"
  51. #string STR_AUTHEN_TYPE_KERBEROS #language en-US "Kerberos"
  52. #string STR_AUTHEN_TYPE_NONE #language en-US "None"
  53. #string STR_ISCSI_LOCAL_IP_ADDRESS #language en-US " Initiator IP Address"
  54. #string STR_ISCSI_LOCAL_MASK #language en-US " Initiator Subnet Mask"
  55. #string STR_ISCSI_LOCAL_GATEWAY #language en-US " Gateway"
  56. #string STR_ISCSI_IP_ADDRESS_HELP #language en-US "Enter IP address in dotted-decimal notation."
  57. #string STR_ISCSI_TARGET_NAME #language en-US " Target Name"
  58. #string STR_ISCSI_TARGET_NAME_HELP #language en-US "The worldwide unique name of the target. Only iqn. format is accepted."
  59. #string STR_ISCSI_TARGET_ADDRESS #language en-US " Target Address"
  60. #string STR_ISCSI_TARGET_ADDRESS_HELP #language en-US "Enter Target address in IPv4,IPv6 or URL format.You need to configure DNS server address in advance if input a URL string."
  61. #string STR_ISCSI_TARGET_PORT #language en-US " Target Port"
  62. #string STR_ISCSI_BOOT_LUN #language en-US " Boot LUN"
  63. #string STR_ISCSI_BOOT_LUN_HELP #language en-US "Hexadecimal representation of the LU number. Examples are: 4752-3A4F-6b7e-2F99, 6734-9-156f-127, 4186-9"
  64. #string STR_ISCSI_ENABLE_DHCP #language en-US "Enable DHCP"
  65. #string STR_ISCSI_ENABLE_DHCP_ON_TARGET #language en-US "Get target info via DHCP"
  66. #string STR_CHAP_TYPE_PROMPT #language en-US " CHAP Type"
  67. #string STR_CHAP_TYPE_HELP #language en-US "None, One way CHAP or mutual CHAP"
  68. #string STR_CHAP_TYPE_UNI #language en-US "One way"
  69. #string STR_CHAP_TYPE_MUTUAL #language en-US "Mutual"
  70. #string STR_ISCSI_CHAP_NAME #language en-US " CHAP Name"
  71. #string STR_ISCSI_CHAP_SECRET #language en-US " CHAP Secret"
  72. #string STR_ISCSI_CHAP_SECRET_HELP #language en-US "The minimum length is 12 bytes and the maximum length is 16 bytes."
  73. #string STR_ISCSI_REVERSE_CHAP_NAME #language en-US " Reverse CHAP Name"
  74. #string STR_ISCSI_REVERSE_CHAP_SECRET #language en-US " Reverse CHAP Secret"
  75. #string STR_RETURN_MAIN_FORM #language en-US "Back to Previous Page"
  76. #string STR_SAVE_CHANGES #language en-US "Save Changes"
  77. #string STR_SAVE_CHANGES_HELP #language en-US "Must reboot system manually for changes to take place."
  78. #string STR_NULL #language en-US ""
  79. #string STR_SAVE_AND_EXIT #language en-US "Commit Changes and Exit"
  80. #string STR_NO_SAVE_AND_EXIT #language en-US "Discard Changes and Exit"
  81. #string STR_ISCSI_CONFIG_ISID #language en-US "ISID"
  82. #string STR_ISCSI_CONFIG_ISID_HELP #language en-US "OUI-format ISID in 6 bytes, default value are derived from MAC address. Only last 3 bytes are configurable. Example: update 0ABBCCDDEEFF to 0ABBCCF07901 by input F07901."
  83. #string STR_ISCSI_MAC_PROMPT #language en-US "Configure the mac address for the attempt"
  84. #language x-UEFI-ns "iSCSIMacAddr"
  85. #string STR_ISCSI_ADD_ATTEMPTS #language en-US "Add Attempts"
  86. #language x-UEFI-ns "iSCSIAddAttempts"
  87. #string STR_ISCSI_DELETE_ATTEMPTS #language en-US "Delete Attempts"
  88. #language x-UEFI-ns "iSCSIDeleteAttempts"
  89. #string STR_ISCSI_DISPLAY_ATTEMPTS #language en-US "Display Attempts"
  90. #language x-UEFI-ns "iSCSIDisplayAttemptList"
  91. #string STR_ISCSI_ATTEMPT_ORDER #language en-US "New Attempt Order"
  92. #language x-UEFI-ns "iSCSIAttemptOrder"
  93. #string STR_ISCSI_ISID_HELP #language en-US "The iSCSI ISID. Default value are derived from MAC address. Only last 3 bytes are configurable."